翻訳と辞書
Words near each other
・ "O" Is for Outlaw
・ "O"-Jung.Ban.Hap.
・ "Ode-to-Napoleon" hexachord
・ "Oh Yeah!" Live
・ "Our Contemporary" regional art exhibition (Leningrad, 1975)
・ "P" Is for Peril
・ "Pimpernel" Smith
・ "Polish death camp" controversy
・ "Pro knigi" ("About books")
・ "Prosopa" Greek Television Awards
・ "Pussy Cats" Starring the Walkmen
・ "Q" Is for Quarry
・ "R" Is for Ricochet
・ "R" The King (2016 film)
・ "Rags" Ragland
・ ! (album)
・ ! (disambiguation)
・ !!
・ !!!
・ !!! (album)
・ !!Destroy-Oh-Boy!!
・ !Action Pact!
・ !Arriba! La Pachanga
・ !Hero
・ !Hero (album)
・ !Kung language
・ !Oka Tokat
・ !PAUS3
・ !T.O.O.H.!
・ !Women Art Revolution


Dictionary Lists
翻訳と辞書 辞書検索 [ 開発暫定版 ]
スポンサード リンク

critical relative humidity : ウィキペディア英語版
critical relative humidity
The critical relative humidity (CRH) of a salt is defined as the relative humidity of the surrounding atmosphere (at a certain temperature) at which the material begins to absorb moisture from the atmosphere and below which it will not absorb atmospheric moisture.
When the humidity of the atmosphere is equal to (or is greater than) the critical relative humidity of a sample of salt, the sample will take up water until all of the salt is dissolved to yield a saturated solution. All water-soluble salts and mixtures have characteristic critical humidities; it is a unique material property.
The critical relative humidity of most salts decreases with increasing temperature. For instance, the critical relative humidity of ammonium nitrate decreases 22% with a temperature from 0°C to 40°C (32°F to 104°F).
The critical relative humidity of several fertilizer salts is given in table 1:
Table 1: Critical relative humidities of pure salts at 30°C.
Mixtures of salts usually have lower critical humidities than either of the constituents. Fertilizers that contain Urea as an ingredient usually exhibit a much lower Critical Relative Humidity than Fertilizers without Urea.Table 2 shows CRH data for two-component mixtures:
Table 2: Critical relative humidities of mixtures of salts at 30°C (values are percent relative humidity).
As shown, the effect of salt mixing is most dramatic in the case of ammonium nitrate with urea. This mixture has an extremely low critical relative humidity and can therefore only be used in liquid fertilisers (so called UAN-solutions).
== See also ==

* Deliquescent
* Hygroscopy
* Humidity

抄文引用元・出典: フリー百科事典『 ウィキペディア(Wikipedia)
ウィキペディアで「critical relative humidity」の詳細全文を読む



スポンサード リンク
翻訳と辞書 : 翻訳のためのインターネットリソース

Copyright(C) kotoba.ne.jp 1997-2016. All Rights Reserved.